<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>TIF | Advanced Test Products Bosch Automotive Service Solutions GmbH</title>
	<atom:link href="https://bosch.entstehthier.de/en/brand/tif/feed/" rel="self" type="application/rss+xml" />
	<link>https://bosch.entstehthier.de/en/</link>
	<description>Geräte zur Installation und Wartung von Kälte-/Klima Installationen</description>
	<lastBuildDate>Thu, 25 Sep 2025 07:53:15 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://bosch.entstehthier.de/wp-content/uploads/2024/02/cropped-Unbenannt-2-32x32.jpg</url>
	<title>TIF | Advanced Test Products Bosch Automotive Service Solutions GmbH</title>
	<link>https://bosch.entstehthier.de/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TIF 9030E</title>
		<link>https://bosch.entstehthier.de/en/produkt/tif-9030e/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 23 Mar 2023 07:49:54 +0000</pubDate>
				<guid isPermaLink="false">https://bosch.entstehthier.de/produkt/tif-9030e/</guid>

					<description><![CDATA[Compact Refrigerant Scale up to 100 kg]]></description>
										<content:encoded><![CDATA[<div>
<h4>Features</h4>
</div>
<div>
<ul>
<li>Compact design</li>
<li>Extremely durable</li>
<li>Range up to 100 kg</li>
<li>Display weight in <span class="roter-Punkt char-style-override-11">kg</span>, <span class="roter-Punkt">oz</span>, lbs</li>
<li>Resolution 10 g</li>
<li>Easy to use: ON/OFF &#8211; UNITS &#8211; ZERO buttons</li>
<li>9 V battery operated</li>
<li>Overload protected</li>
<li>Inclusive Shoulder bag </li>
<li>CE approved</li>
<li>One year warranty</li>
</ul>
<div>
<h4>Specifications</h4>
</div>
<table id="table-50" class="Tabelle">
<colgroup>
<col class="Row-Column-48">
<col class="Row-Column-49"></colgroup>
<tbody>
<tr class="Row-Column-30">
<td>
<p class="Tabelle-klein">Measurement range</p>
</td>
<td>
<p class="Tabelle-klein">0 kg to 100 kg or</p>
<p class="Tabelle-klein">0 lbs 0oz to 199 lbs 15 oz or</p>
<p class="Tabelle-klein">0.00 lbs to 199.99 lbs</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Resolution</p>
</td>
<td>
<p class="Tabelle-klein">0.01 kg or 0.05 lbs</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±0.5 % of reading ±1 digit</p>
</td>
</tr>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">Power Supply
</p>
</td>
<td>
<p class="Tabelle-klein">One 9 V alkaline battery</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Battery Life</p>
</td>
<td>
<p class="Tabelle-klein">Life 20 hours (approx.)</p>
</td>
</tr>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">Operating Temperature
</p>
</td>
<td>
<p class="Tabelle-klein">-10 °C to 49 °C</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Weight</p>
</td>
<td>
<p class="Tabelle-klein">2,36 kg</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Dimensions</p>
</td>
<td>
<p class="Tabelle-klein">304,8 x 431,8 x 57,1 mm</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Standard Accessories</p>
</td>
<td>
<p class="Tabelle-klein">Battery and nylon carrying case </p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="pruefzeichen"><img decoding="async" class="alignleft wp-image-158 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/CE_logo.jpg" alt="" width="69" height="50" /><img loading="lazy" decoding="async" class="alignleft wp-image-160 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/UKCA_logo.jpg" alt="" width="53" height="50" /></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TIF 7620</title>
		<link>https://bosch.entstehthier.de/en/produkt/tif-7620/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 21 Mar 2023 14:56:40 +0000</pubDate>
				<guid isPermaLink="false">https://bosch.entstehthier.de/produkt/tif-7620/</guid>

					<description><![CDATA[Infrared thermometer with point laser, 20:1]]></description>
										<content:encoded><![CDATA[<p>Instant contactless temperature measurements using advanced infrared technology.</p>
<div>
<h4>Features</h4>
</div>
<div>
<ul>
<li>Temperature Measurement Range -60 °C to +760 °C (-76 °F to +1400 °F)</li>
<li>Response time 0.5 sec.</li>
<li>LCD display backlit</li>
<li>Battery level indication</li>
<li>Auto power off after 15 sec.</li>
<li>Automatic Max and Data Hold for 10 sec.</li>
<li>Adjustable alarm, Max/Min</li>
<li>Adjustable emission factor</li>
<li>External contact temperature sensor can be connected</li>
<li>Point laser for marking the measuring field</li>
<li>The optical resolution (ratio of distance to measuring field diameter) of up to 20:1 also enables measurement of small objects from a greater distance.</li>
<li>After the measurement, the measured value and the max value are automatically held and displayed by the Hold function.</li>
</ul>
<h4>Specifications</h4>
<table id="table-161" class="Tabelle">
<colgroup>
<col class="Row-Column-138">
<col class="Row-Column-166"></colgroup>
<tbody>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Temperature measurement range</p>
</td>
<td>
<p class="Tabelle-klein">-60 °C to 760 °C</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Optical</p>
</td>
<td>
<p class="Tabelle-klein">20:1</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Resolution</p>
</td>
<td>
<p class="Tabelle-klein">0,1 °C / 0,1 °F (1° below 9,9 °C and above 199,9 °C)</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Emissivity setting</p>
</td>
<td>
<p class="Tabelle-klein">Adjustable</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Adjustable alarm, Max/Min</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">external connection for</p>
<p class="Tabelle-klein">K-temperature adapter</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Measuring range with</p>
<p class="Tabelle-klein">K-temperature adapter</p>
</td>
<td>
<p class="Tabelle-klein">-64 °C to 1400 °C</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±2 % of reading or ±0 °C (4 °F)</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Response Time</p>
</td>
<td>
<p class="Tabelle-klein">0,5 sec</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Size W x H x D</p>
</td>
<td>
<p class="Tabelle-klein">39 x 175 x 72 mm</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Operating temperature range</p>
</td>
<td>
<p class="Tabelle-klein">0 &#8211; 50 °C / &lt;80 % RH</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Weight</p>
</td>
<td>
<p class="Tabelle-klein">179 g</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Battery lifetime, operating time, approx.</p>
</td>
<td>
<p class="Tabelle-klein">appr. 18 hours</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Power supply</p>
</td>
<td>
<p class="Tabelle-klein">2 x 1,5 V batteries (AAA)</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Standard Accessories</p>
</td>
<td>
<p class="Tabelle-klein">Including batteries, thermo- couple and protective case</p>
</td>
</tr>
</tbody>
</table>
</div>
<div>
<h4>Applications</h4>
</div>
<div>
<p class="Flie-text">Detect heating of problem fuses, wires, insulators, connectors, splices, switches, neutrals or overloaded motors due to possible Harmonic currents. Check temperature of high voltage equipment and transformers from a safe distance</p>
</div>
<div class="pruefzeichen"><img loading="lazy" decoding="async" class="alignleft wp-image-158 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/CE_logo.jpg" alt="" width="69" height="50"><img loading="lazy" decoding="async" class="alignleft wp-image-160 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/UKCA_logo.jpg" alt="" width="53" height="50"></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TIF 7612</title>
		<link>https://bosch.entstehthier.de/en/produkt/tif-7612/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 21 Mar 2023 14:44:11 +0000</pubDate>
				<guid isPermaLink="false">https://bosch.entstehthier.de/produkt/tif-7612/</guid>

					<description><![CDATA[Infrarot-Thermometer mit Punktlaser, 12:1]]></description>
										<content:encoded><![CDATA[<p>Instant contactless temperature measurements using advanced infrared technology.</p>
<h4>Features</h4>
<div>
<ul>
<li>Temperature Measurement Range -60 °C to +500 °C (-76 °F to +932 °F)</li>
<li>Response time 0.5 sec.</li>
<li>LCD display backlit</li>
<li>Battery level indication</li>
<li>Auto power off after 15 sec.</li>
<li>Automatic Max and Data Hold for 10 sec.</li>
<li>Adjustable alarm, Max/Min</li>
<li>Adjustable emission factor</li>
<li>External contact temperature sensor can be connected</li>
<li>Point laser for marking the measuring field</li>
<li>Innovative optical lens – high accuracy measurements over wide temperature ranges 12:1 Distance to Spot (D:S) ratio</li>
<li>After the measurement, the measured value and the max value are automatically held and displayed by the Hold function.</li>
</ul>
<h4>Specifications</h4>
<table id="table-160" class="Tabelle">
<colgroup>
<col class="Row-Column-138">
<col class="Row-Column-166"></colgroup>
<tbody>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Temperature measurement range</p>
</td>
<td>
<p class="Tabelle-klein">-60 °C to 500 °C</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Optical</p>
</td>
<td>
<p class="Tabelle-klein">12:1</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Resolution</p>
</td>
<td>
<p class="Tabelle-klein">0,1 °C / 0,1 °F (1° below 9,9 °C and above 199,9 °C)</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Emissivity setting</p>
</td>
<td>
<p class="Tabelle-klein">Adjustable</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Adjustable alarm,<br />
Max/Min</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">external connection for</p>
<p class="Tabelle-klein">K-temperature adapter</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Measuring range with</p>
<p class="Tabelle-klein">K-temperature adapter</p>
</td>
<td>
<p class="Tabelle-klein">-64 °C to 1400 °C</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±2 % of reading or ±0 °C (4 °F)</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Response Time</p>
</td>
<td>
<p class="Tabelle-klein">0,5 sec</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Size W x H x D</p>
</td>
<td>
<p class="Tabelle-klein">39 x 175 x 72 mm</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Operating temperature range</p>
</td>
<td>
<p class="Tabelle-klein">0 &#8211; 50 °C / &lt;80 % RH</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Weight</p>
</td>
<td>
<p class="Tabelle-klein">179 g</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Battery lifetime, operating time, approx.</p>
</td>
<td>
<p class="Tabelle-klein">appr. 18 hours</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Power supply</p>
</td>
<td>
<p class="Tabelle-klein">2 x 1,5 V batteries (AAA)</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Standard Accessories</p>
</td>
<td>
<p class="Tabelle-klein">Including batteries, thermo- couple and protective case</p>
</td>
</tr>
</tbody>
</table>
</div>
<h4>Applications</h4>
<p>Detect heating of problem fuses, wires, insulators, connectors, splices, switches, neutrals or overloaded motors due to possible Harmonic currents. Check temperature of high voltage equipment and transformers from a safe distance</p>
<div class="pruefzeichen"><img loading="lazy" decoding="async" class="alignleft wp-image-158 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/CE_logo.jpg" alt="" width="69" height="50"><img loading="lazy" decoding="async" class="alignleft wp-image-160 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/UKCA_logo.jpg" alt="" width="53" height="50"></div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TIF 7201</title>
		<link>https://bosch.entstehthier.de/en/produkt/tif-7201/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 21 Mar 2023 14:33:42 +0000</pubDate>
				<guid isPermaLink="false">https://bosch.entstehthier.de/produkt/tif-7201/</guid>

					<description><![CDATA[Contactless temperature measurement in seconds through innovative infrared technology]]></description>
										<content:encoded><![CDATA[<div class="pruefzeichen">
<div>
<p class="Flie-text">Mini infrared thermometer is lightning fast and precise. Measures even small objects. After the measurement the current value and the maximum value are automatically stored and displayed.</p>
</div>
<div>
<h4>Features</h4>
</div>
<div>
<ul>
<li>System-on-a-Chip SoC technology: compact and lightweight</li>
<li>Measuring range -33 °C to 220 °C</li>
<li>Response time 0.5 sec.</li>
<li>automatic max function </li>
<li>Backlit LCD display w/ dual readings</li>
<li>Battery level indication</li>
<li>Auto power off after 15 sec.</li>
</ul>
<h4>Specifications</h4>
<table id="table-159" class="Tabelle">
<colgroup>
<col class="Row-Column-28">
<col class="Row-Column-29"></colgroup>
<tbody>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Temperature measurement range</p>
</td>
<td>
<p class="Tabelle-klein">-33 °C to +220 °C (-27 °F to +428 °F)</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Optical</p>
</td>
<td>
<p class="Tabelle-klein">1:1</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Resolution</p>
</td>
<td>
<p class="Tabelle-klein">0,1 °C</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Emissivity setting</p>
</td>
<td>
<p class="Tabelle-klein">0,95 fixed</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±2 % of reading or ±0 °C (4 °F)</p>
</td>
</tr>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">Operating temperature range</p>
</td>
<td>
<p class="Tabelle-klein">-10 °C to +50 °&lt;C (14 °F to +122 °F)</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Dimensions<br />
W x H x D</p>
</td>
<td>
<p class="Tabelle-klein">35 x 100 x 25 mm</p>
</td>
</tr>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">Battery<br />
life</p>
</td>
<td>
<p class="Tabelle-klein">20 hours</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Weight</p>
</td>
<td>
<p class="Tabelle-klein">40 g</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Power supply</p>
</td>
<td>
<p class="Tabelle-klein">CR2032 lithium cell battery</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Standard Accessories</p>
</td>
<td>
<p class="Tabelle-klein">Batteries</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="pruefzeichen"><img loading="lazy" decoding="async" class="alignleft wp-image-158 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/CE_logo.jpg" alt="" width="69" height="50"><img loading="lazy" decoding="async" class="alignleft wp-image-160 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/UKCA_logo.jpg" alt="" width="53" height="50"></div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TIF 175</title>
		<link>https://bosch.entstehthier.de/en/produkt/tif-175/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 17 Mar 2023 11:52:38 +0000</pubDate>
				<guid isPermaLink="false">https://bosch.entstehthier.de/produkt/tif-175/</guid>

					<description><![CDATA[TRMS AC/DC Clamp-On Ammeter DMM]]></description>
										<content:encoded><![CDATA[<div class="product-info-description col-md-8">
<div class="nav-tabs-container has-multi-tabs">
<div class="tab-content">
<div class="tab-pane active">
<div class="tab-body active">
<div>
<h4>Features</h4>
</div>
<div>
<ul>
<li>DC and True RMS AC voltage and current measurements up to 600 V</li>
<li>Non-contact voltage sensor integrated into clamp</li>
<li>Also includes Resistance, Frequency, Diode Test, Capacitance</li>
<li>Temperature reading with Type-K probe</li>
<li>Data Hold, MIN/MAX and Relative readings</li>
<li>Bargraph</li>
<li>Backlight display</li>
<li>Auto Power Off</li>
<li>CAT IV, 600 V</li>
</ul>
</div>
<div>
<h4>Specifications</h4>
</div>
<table id="table-151" class="Tabelle">
<colgroup>
<col class="Row-Column-65">
<col class="Row-Column-88"></colgroup>
<tbody>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">TRMS</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Voltage AC</p>
</td>
<td>
<p class="Tabelle-klein">1 mV &#8211; 1000 V</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±1,0 % rdg ±4 digits</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Voltage DC</p>
</td>
<td>
<p class="Tabelle-klein">0,01 mV &#8211; 1000 V</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±1,0 % rdg ±3 digits</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Current AC</p>
</td>
<td>
<p class="Tabelle-klein">0,01-600 A</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Current DC</p>
</td>
<td>
<p class="Tabelle-klein">0,01-600 A</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±2,0 % rdg ±8 digits</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Frequency</p>
</td>
<td>
<p class="Tabelle-klein">0,01 Hz &#8211; 60 kHz</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±1,0 % rdg ±5 digits</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Resistance</p>
</td>
<td>
<p class="Tabelle-klein">0,1 Ω &#8211; 60 MΩ</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Accuracy</p>
</td>
<td>
<p class="Tabelle-klein">±1,0 % rdg ±5 digits</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Continuity Test</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Capacitance</p>
</td>
<td>
<p class="Tabelle-klein">0,1 nF &#8211; 4 mF</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Diode Test</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Temperature</p>
</td>
<td>
<p class="Tabelle-klein">-20 &#8211; 760 °C</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Non-contact<br />
voltage measurement</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Duty Cycle</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Data HOLD</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Bargraph</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Relative Measurement</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">MAX/MIN readings</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Peak HOLD</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Backlight</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Auto Power Off</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Power supply</p>
</td>
<td>
<p class="Tabelle-klein">1 x 9 V battery</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Battery Life</p>
</td>
<td>
<p class="Tabelle-klein">max. max. 200 hours </p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Display</p>
</td>
<td>
<p class="Tabelle-klein">4 Digit LCD</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Safety</p>
</td>
<td>
<p class="Tabelle-klein">IEC/EN 61010-1</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Measuring Category</p>
</td>
<td>
<p class="Tabelle-klein">CAT IV, 600 V CAT III, 1000 V</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Size / Weight</p>
</td>
<td>
<p class="Tabelle-klein">210 x 75 x 45 mm / 400 g</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Max. Dia of wire</p>
</td>
<td>
<p class="Tabelle-klein">30 mm</p>
</td>
</tr>
</tbody>
</table>
<div>
<h4>Replacement Parts</h4>
</div>
<div>
<table id="table-150" class="Tabelle">
<colgroup>
<col class="Row-Column-65">
<col class="Row-Column-88"></colgroup>
<tbody>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">TIF 4413-2</p>
</td>
<td>
<p class="Tabelle-klein">Replacement Test Leads</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">TIF TK101</p>
</td>
<td>
<p class="Tabelle-klein">Type-K Thermocouple probe</p>
</td>
</tr>
</tbody>
</table>
</div>
<div class="pruefzeichen"><img loading="lazy" decoding="async" class="alignleft wp-image-158 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/CE_logo.jpg" alt="" width="69" height="50"><img loading="lazy" decoding="async" class="alignleft wp-image-160 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/UKCA_logo.jpg" alt="" width="53" height="50"></div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TIF XP-1A</title>
		<link>https://bosch.entstehthier.de/en/produkt/tif-xp-1a/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 16 Mar 2023 09:10:54 +0000</pubDate>
				<guid isPermaLink="false">https://bosch.entstehthier.de/produkt/tif-xp-1a/</guid>

					<description><![CDATA[Refrigerant Leak Detector]]></description>
										<content:encoded><![CDATA[<div>
<h4>Features</h4>
</div>
<div>
<ul>
<li>Corona Discharge Sensor, proven technology</li>
<li>Microprocessor controlled circuit with Advanced Digital Signal Processing, monitors the sensing tip up to 2000 times per second</li>
<li>Detects all halogenated refrigerants, including A2L refrigerants</li>
<li>Variable frequency audible alarm</li>
<li>14&#8243; Flexible stainless steel probe with Teflon™ liner</li>
<li>Rubber cushion grip</li>
<li>Constant power indication</li>
<li>Power supply 3 V DC, two “C” cell alkaline batteries (included)</li>
<li>Sensing tip life: approx. 20 hours (two tips included)</li>
<li>Operating temp. -20° to 52° C</li>
<li>Blow molded carrying case included, optional holster</li>
<li>CE approved</li>
<li>Two year warranty</li>
</ul>
<h4>Specifications</h4>
<table id="table-18" class="Tabelle">
<colgroup>
<col class="Row-Column-33" />
<col class="Row-Column-34" /></colgroup>
<tbody>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Ultimate Sensitivity</p>
</td>
<td>
<p class="Tabelle-klein">&lt; &lt; 3 g/year (0.1 oz/year)</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">True Mechanical Pump</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">Visual Leak Indication Levels</p>
</td>
<td>
<p class="Tabelle-klein">18 (tri-color)</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Sensitivity Levels</p>
</td>
<td>
<p class="Tabelle-klein">7</p>
</td>
</tr>
<tr class="Row-Column-35">
<td>
<p class="Tabelle-klein">One Touch Reset and Keypad Controls</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">Mute Button</p>
</td>
<td>
<p class="Tabelle-klein">yes</p>
</td>
</tr>
<tr class="Row-Column-25">
<td>
<p class="Tabelle-klein">Battery Test</p>
</td>
<td>
<p class="Tabelle-klein">True voltage indication</p>
</td>
</tr>
<tr class="Row-Column-24">
<td>
<p class="Tabelle-klein">Battery Life</p>
</td>
<td>
<p class="Tabelle-klein">Approx. 30 hours</p>
</td>
</tr>
</tbody>
</table>
<h4>Optional Accessories</h4>
<table id="table-20" class="Tabelle">
<colgroup>
<col class="Row-Column-26" />
<col class="Row-Column-27" /></colgroup>
<tbody>
<tr class="Row-Column-23">
<td>
<p class="Tabelle-klein">Maintenance Kit</p>
<p class="Tabelle-klein">(3 Tips with protectors)</p>
</td>
<td>
<p class="Tabelle-klein">TIF XP-2</p>
</td>
</tr>
</tbody>
</table>
</div>
<h4>Refrigerants</h4>
<table id="table-17" class="Tabelle">
<colgroup>
<col class="Row-Column-18" />
<col class="Row-Column-19" /></colgroup>
<tbody>
<tr class="Row-Column-20">
<td class="cell-style-override-2">
<p class="Tabelle-klein">CFC</p>
</td>
<td class="cell-style-override-2">
<p class="Tabelle-klein">e.g. R12</p>
</td>
</tr>
<tr class="Row-Column-20">
<td class="cell-style-override-2">
<p class="Tabelle-klein">HCFC</p>
</td>
<td class="cell-style-override-2">
<p class="Tabelle-klein">e.g. R22, 502</p>
</td>
</tr>
<tr class="Row-Column-21">
<td class="cell-style-override-2">
<p class="Tabelle-klein">HFC</p>
</td>
<td class="cell-style-override-2">
<p class="Tabelle-klein">e.g. R134a, 404a, 125, 410A</p>
</td>
</tr>
<tr class="Row-Column-20">
<td class="cell-style-override-2">
<p class="Text-mit-roten-Punkten"><span class="roter-Punkt char-style-override-11">Replacements</span></p>
</td>
<td class="cell-style-override-2">
<p class="Tabelle-klein">e.g. AZ-50, HP 62, MP 39, R1234yf, R32</p>
</td>
</tr>
</tbody>
</table>
<div class="pruefzeichen"><img loading="lazy" decoding="async" class="alignleft wp-image-158 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/CE_logo.jpg" alt="" width="69" height="50" /><img loading="lazy" decoding="async" class="alignleft wp-image-162 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/UL_logo.jpg" alt="" width="56" height="50" /><img loading="lazy" decoding="async" class="alignleft wp-image-160 size-full" src="https://bosch.entstehthier.de/wp-content/uploads/2023/03/UKCA_logo.jpg" alt="" width="53" height="50" /></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>